17600 – System Data
System data consists of 18 bytes. The first two bytes have the current alarm contact
settings (big-endian). Each bit corresponds to a contact. Bit 0 (lsb) of byte 1 is the bit for
the Power Supply 1 alarm, and bit 7 (msb) is the bit for the 'any' alarm. The next five bytes
are for the installed card inventory. A '0' bit means the card is installed and a '1' bit means
the card is removed. The other bytes are for internal use.
17601:17636 – Card Data
Each I/O card in the HDxRouter has an associated TCP port. Card 1 uses port 17601, card
2 uses 17602, and so on. The data is formatted as follows:
12 bytes, internal use
1 byte, card type
0xff missing
0x01 downstream
SFP data, 256 bytes per SFP, 16 SFPs per card
128 bytes, SFP ID data
128 bytes, SFP diagnostic data
Nov 3, 2014 Router Interfaces: HX576 17/25
Table 5: Hx576 System Data