Thinklogical Secure Console Server Manual Manual de usuario Pagina 79

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 90
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 78
S e c u r e C o n s o l e S e r v e r M a n u a l , R e v . K
, J u l y , 2 0 1 3
Page 79
#CBS1 Enables local and remote callback security.
#CBS2 Enables remote callback security only.
#CBS3 Disables callback security until local hangup or reset.
Command: #Pn Set 11-bit Parity
Values: n = 0 or 1
Default: 2
Description: #P0 No parity.
#P1 Odd parity.
#P2 Even parity.
Command: #Sx Enter Setup Password
Values: x= password (1–8 characters, case sensitive)
Default: MTSMODEM
Description: Enters the callback security setup password.
Command: #S=x Store Setup Password
Values: x= password (1–8 characters, case sensitive)
Default: MTSMODEM
Description: Stores a new callback security and remote configuration setup password.
S-Registers
Certain modem values, or parameters, are stored in memory locations called S-Registers. Use
the S command to read or to alter the contents of S-Registers (see previous section).
Register
Unit Range Default Description
S0
1 ring 0, 1–255 1
Sets the number of rings until the modem answers. ATS0=0 disables auto
answer completely.
S1
1 ring 0–255 0 Counts the rings that have occurred.
S2
decimal 0–127 43 (+) Sets ASCII code for the escape sequence character.
128–255 Values greater than 127 disable escape.
S3
decimal 0–127 13 (^M) Sets the ASCII code for the carriage return character.
S4
decimal 0–127 10 (^J) Sets the ASCII code for the line feed character.
S5
decimal 0–32 8 (^H) Sets the ASCII code for the backspace character.
33–1 27 Values greater than 32 disable backspace.
S6
seconds 2–65* 2*
Sets the time the modem waits after it goes off-hook before it begins to dial the
telephone number.
S7
seconds 35-65* 50*
Sets the time the modem waits for a carrier signal before aborting a call. Also
sets the wait for silence time for the @ dial modifier.
S8
seconds 0–65 2
Sets the length of a pause caused by a comma character in a dialing com-
mand.
S9
decimal 0, 1–127 37 (%)
Sets ASCII code for remote configuration escape character. S9=0 disables
remote configuration.
S10
100 ms 1–254 20 Sets how long a carrier signal must be lost before the modem disconnects.
S11
1 ms 50–1 50* 95* Sets spacing and duration of dialing tones.
S28
decimal 0, 1–255 1 0 disables, 1–255 enables V.34 modulation.
S30
1 minute 0, 1–255 0
Sets the length of time that the modem waits before disconnecting when no
data is sent or received. A value of zero disables the timer. See also the \T
command
S35
decimal 0–1 1
0 disables, 1 enables the V.25 calling tone, which allows remote data/fax/voice
discrimination.
S36
decimal 0–7 7
Specifies the action to take in the event of a negotiation failure when error control
is selected. (See S48.)
S37
decimal 0–19 0
Sets the maximum V.34 “upstream” speed at which the modem attempts to
connect.
Vista de pagina 78