TLX Matrix Switch SNMP Traps Manual 14 Rev. E - July, 2015
High Temperature Begin and Clear Contact 5
The system has detected a temperature that is above the preset alarm threshold (Begin) or is now below the
preset alarm threshold (Clear).
Begin OID: 1,3,6,1,4,1,17658,3,14,0,9
Clear OID: 1,3,6,1,4,1,17658,3,14,0,10
Objects:
1: sysContact
2: sysDescr
3: sysLocation
4: sysName
CPU Error Begin and Clear Contact 6
The system has detected a CPU fault (Begin) or the fault is now gone (Clear).
Begin OID: 1,3,6,1,4,1,17658,3,14,0,11
Clear OID: 1,3,6,1,4,1,17658,3,14,0,12
Objects:
1: sysContact
2: sysDescr
3: sysLocation
4: sysName
I/O Card Error Begin and Clear Contact 7
The system has detected an error in one of the I/O cards (Begin) or the card is now error free (Clear).
Begin OID: 1,3,6,1,4,1,17658,3,14,0,13
Clear OID: 1,3,6,1,4,1,17658,3,14,0,14
Objects:
1: sysContact
2: sysDescr
3: sysLocation
4: sysName